The A-One Business Center is a 9-building landmark that offers two building type configurations; A & B. The Summary of physical properties & technical specifications hereunder is the same for both building configuration types.
PHYSICAL PROPERTIES
|
Construction Dates: |
From Fall 2006 to Winter 2009 |
|
Total Rentable Area: |
37’200 square meters net |
|
Average Floor Plates: |
Buildings A2 to A5: |
|
Ground floor: |
628 square meters (net) |
|
Upper floors: |
693 square meters (net) |
|
Buildings B1 to B4: |
|
|
Ground floor: |
1’610 square meters (net) |
|
Upper floors: |
1’795 square meters (net) |
|
Number of floors |
|
|
All Buildings: |
3 (except Building B1: 4 floors) |
|
Building Height: |
11,1 meters (except building B1: 14,4 meters) |
|
Windows: |
Reflective double-glazed, solar insulated (SIA 380/1) |
|
|
32 to 35 dB |
|
Restrooms |
|
|
Buildings A: |
2 per floor (handicapped accessible) |
|
Buildings B: |
4 per floor (handicapped accessible) |
|
Structure: |
Poured concrete reinforced with re-bars |
|
Floor Loading: |
|
|
Ground floor: |
500 kg per square meter |
|
All other floors: |
300 kg per square meter |
|
Exterior Cladding: |
Double-glazed insulated glass and steel. |
|
Exterior blinds: |
electrically controlled |
|
Ceiling Height: |
Ground floor: 3,9 meters, slab to slab; 3,20 meters useful |
|
Other floors: |
3,4 meters, slab to slab; 2,70 meters useful |
HEATING VENTILATION AND AIR CONDITIONING
|
Air Quality Standard: |
Industry standards are met or exceeded. SIA 382/1 and SIA 2021 |
|
A/C and Heating: |
Variable Air Volume system. Pulsed air at 20°C all year round. SIA 382/1 and SIA 2021 |
|
Facility Management System: |
Computerized state-of-the-art digital control and monitoring system for environmental control and energy management. |
SECURITY & LIFE SAFETY
|
Type of System: |
Building entrance doors equipped with electronic locks. |
|
Security System: |
The base building security system can incorporate fully integrated access control and alarm monitoring software packages for the tenant. |
|
Sprinklers: |
Fully sprinklered buildings. |
|
Fire Detection Service: |
Heat and smoke detection devices provided to meet code requirements. |
|
Emergency Exits: |
Buildings A: 2 emergency exit stairways. Buildings B: 3 emergency exit stairways. |
ELEVATORS
|
|
Designed to meet requirements for handicapped personnel. Capacity 1’000 kg. |
COMMUNICATION FACILITIES
|
Telephone: |
Telephone closets with riser cables serving each floor. All Telephone Equipment must be installed within Tenant space. |
|
Fiber Optics: |
Fiber optic cable will be installed. |
|
Data Center: |
All rented space equipped with local IT Room (fully air-conditioned). |